1. 개별 instance 값 설정
  ce0 : 100fdx / ce1 : 10fdx / ce2 : 100fdx / ce3 : 100fdx / ce4 : 100fdx / ce5 : 10fdx

# grep ce /etc/path_to_inst
"/pci@8,700000/pci@2/pci@0/network@0" 2 "ce"
"/pci@8,700000/pci@2/pci@0/network@1" 3 "ce"
"/pci@8,700000/pci@2/pci@4/network@2" 4 "ce"
"/pci@8,700000/pci@2/pci@4/network@3" 5 "ce"
"/pci@9,700000/usb@1,3/device@1" 0 "usb_mid"
"/pci@9,700000/usb@1,3/device@1/keyboard@0" 2 "hid"
"/pci@9,700000/usb@1,3/device@1/mouse@1" 3 "hid"
"/pci@9,700000/network@2" 0 "ce"
"/pci@9,600000/network@1" 1 "ce"

# grep ce /etc/driver_aliases
ce "pci108e,abba"
ce "pci100b,35"

아래파일 생성

# vi /platform/sun4u/kernel/drv/ce.conf
name="pci108e,abba" parent="/pci@9,700000" unit-address="2"
adv_autoneg_cap=0
adv_1000fdx_cap=0
adv_1000hdx_cap=0
adv_100fdx_cap=1
adv_100hdx_cap=0
adv_10fdx_cap=0
adv_10hdx_cap=0;

name="pci108e,abba" parent="/pci@9,600000" unit-address="1"
adv_autoneg_cap=0
adv_1000fdx_cap=0
adv_1000hdx_cap=0
adv_100fdx_cap=0
adv_100hdx_cap=0
adv_10fdx_cap=1
adv_10hdx_cap=0;


name="pci100b,35" parent="/pci@8,700000/pci@2/pci@0" unit-address="0"
adv_autoneg_cap=0
adv_1000fdx_cap=0
adv_1000hdx_cap=0
adv_100fdx_cap=1
adv_100hdx_cap=0
adv_10fdx_cap=0
adv_10hdx_cap=0;

name="pci100b,35" parent="/pci@8,700000/pci@2/pci@0" unit-address="1"
adv_autoneg_cap=0
adv_1000fdx_cap=0
adv_1000hdx_cap=0
adv_100fdx_cap=1
adv_100hdx_cap=0
adv_10fdx_cap=0
adv_10hdx_cap=0;

name="pci100b,35" parent="/pci@8,700000/pci@2/pci@4" unit-address="2"
adv_autoneg_cap=0
adv_1000fdx_cap=0
adv_1000hdx_cap=0
adv_100fdx_cap=1
adv_100hdx_cap=0
adv_10fdx_cap=0
adv_10hdx_cap=0;

name="pci100b,35" parent="/pci@8,700000/pci@2/pci@4" unit-address="3"
adv_autoneg_cap=0
adv_1000fdx_cap=0
adv_1000hdx_cap=0
adv_100fdx_cap=0
adv_100hdx_cap=0
adv_10fdx_cap=1
adv_10hdx_cap=0;


2. 개별 instance값을 없애고 전체 100fdx설정

# vi /platform/sun4u/kernel/drv/ce.conf
adv_autoneg_cap=0
adv_1000fdx_cap=0
adv_1000hdx_cap=0
adv_100T4_cap=0
adv_100fdx_cap=1
adv_100hdx_cap=0
adv_10fdx_cap=0
adv_10hdx_cap=0;

1. 솔라리스 9, 10 동일

 

  1) ifconfig -a 로 네트웍 인터페이스 이름을 알아야 합니다.

    - 화재 서버는 대부분 ce(기가) 아니면 ipge(utp) 입니다.

 

  2) 다음 명령어 실행해서 살펴보면 됩니다.

    kstat -p [인터페이스이름] |grep link_|grep hme0

    -> 결과값의 duplex에서 0 -다운 1-half, 2-full 입니다.

   

i) 네트웍 인터페이스 이름 알기 => ce0,1,2,3 총 4개 존재하는군요.

 

[sfwebd01:/#]ifconfig -a

lo0: flags=1000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4> mtu 8232 index 1

      inet 127.0.0.1 netmask ff000000

ce1: flags=69040843<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER,STANDBY,INACTIVE> mtu 1500 index 17

      inet 210.118.96.126 netmask ffffffc0 broadcast 210.118.96.127

      groupname sfwebd01_ipmp

      ether 0:14:4f:1e:f3:67

ce0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 18

      inet 210.118.96.124 netmask ffffffc0 broadcast 210.118.96.127

      groupname sfwebd01_ipmp

      ether 0:14:4f:1e:cb:a2

ce0:1: flags=9040843<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER> mtu 1500 index 18

      inet 210.118.96.125 netmask ffffffc0 broadcast 210.118.96.127

ce3: flags=69040843<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER,STANDBY,INACTIVE> mtu 1500 index 20

      inet 42.8.35.134 netmask ffffff00 broadcast 42.8.35.255

      groupname sfwebd01

      ether 0:3:ba:da:2:d3

ce2: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 21

      inet 42.8.35.132 netmask ffffff00 broadcast 42.8.35.255

      groupname sfwebd01

      ether 0:14:4f:23:3f:80

ce2:1: flags=9040843<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER> mtu 1500 index 21

      inet 42.8.35.133 netmask ffffff00 broadcast 42.8.35.255

 

ii) 인터페이스별 확인

[sfwebd01:/#]kstat -p ce | grep link_ | grep ce0

ce:0:ce0:link_T4      0

ce:0:ce0:link_asmpause  0

ce:0:ce0:link_duplex  2    <-- 2번이므로 full 연결입니다.

ce:0:ce0:link_pause    0

ce:0:ce0:link_speed    1000  <-- 기가 연결입니다.

ce:0:ce0:link_up      1

 

2. 솔라리스 10 only

  - 솔 10에서는 간단한 명령어가 존재합니다.

  dladm show-dev

 

ex) irdbclt

root@irdbclt # dladm show-dev

ipge0        link: unknown  speed: 1000  Mbps    duplex: full   

ipge1        link: unknown  speed: 1000  Mbps    duplex: full

ce1        link: unknown  speed: 0    Mbps    duplex: unknown

ipge2        link: unknown  speed: 0    Mbps    duplex: unknown

ipge3        link: unknown  speed: 0    Mbps    duplex: unknown

 

사업자 정보 표시
(주)블루원 | 김홍태 | 서울특별시 용산구 원효로 4가 135 금홍 2빌딩 | 사업자 등록번호 : 106-86-76684 | TEL : 02-3272-7200 | Mail : support_ora@blueone.co.kr | 통신판매신고번호 : 호 | 사이버몰의 이용약관 바로가기

'SuperCluster,EXADATA,ODA' 카테고리의 다른 글

IPMP 개요  (0) 2015.12.29
NFS 파일공유 RW 권한 갖는 방법  (0) 2015.12.29
Brocade SAN Switch 설치 및 설정  (0) 2015.12.29
iSCSI 개요  (0) 2015.12.29
Non-Global Zone State Model  (0) 2015.12.29

+ Recent posts